For a library lighting package, start with four functions: general light for circulation, reading light at desks, vertical light on book spines, and adjustable light for displays. Recessed or surface-mounted downlights, suspended or local task lights, shelf lighting or wallwashers, and aimable spotlights or track lights are possible choices. The right combination depends on the furniture layout, ceiling construction and activities in each area.
This KLM customer project provides a supply reference for recessed spotlights, surface-mounted spotlights, track-mounted spotlights, surface downlights and outdoor fittings. The following selection advice explains where each lighting function is useful; the project schedule identifies the configurations supplied. The photographs show the library during fit-out.
Choose library lights by the task they need to perform
Reading tables: even coverage and a comfortable seated view
Use recessed downlights, surface-mounted downlights or suspended luminaires to provide the required light across the table. Add local task lighting where the design needs it. Check the page and computer screen from the actual chair position: an exposed bright source or a reflection on glossy paper can be uncomfortable even when the table looks bright. Specify the workplane target from the applicable project standard, then use the proposed luminaire’s photometric file to check the layout.
Bookshelves: light the spines, including the lowest shelf
Check vertical coverage rather than judging only the brightness of the aisle floor. Depending on shelf height and layout, the solution may use asymmetric shelf luminaires, wallwashers or suitably aimed spotlights. A round downlight centred over an aisle may leave the book faces shaded. For curved shelving like that in the photographs, check coverage at several points along the curve and account for shadows cast by a person standing in front of the books.
Displays and changing layouts: aimable spotlights or track lights
Aimable surface-mounted spotlights and track-mounted spotlights are options for display tables, shelf ends and temporary features. Track can allow the fittings to be repositioned along the installed rail when the display changes. Choose a beam to fit the illuminated object at the actual mounting distance. A narrow beam suits a smaller target; a wider beam can cover a larger target. Verify the required coverage with the model’s photometric data before fixing the layout.
Children’s areas and exterior routes: separate the requirements
In children’s areas, review the view of the fittings from floor-level seating and use controllable scenes where different activities need different light. Exterior routes require their own outdoor-rated fittings, mounting and power arrangements. Confirm the protection rating for each selected outdoor model. These choices are part of the project brief and should be checked separately from the indoor fixture specification.
For the project illustrated here, KLM’s supply included recessed, surface-mounted and track-mounted fittings plus outdoor luminaires. The schedule below shows those ordered selections. Shelf-lighting, pendant and task-light options discussed above are selection guidance for other projects.
Lighting supplied for this library project
| Product type | Ordered configuration | Product enquiry |
|---|---|---|
| Recessed spotlights | DHF, 12W, 15° / 36° / 55° | View DHF series |
| Surface and track spotlights | JH062, 15W; JH050, 10W. Separate surface-mounted and track-mounted versions. | Ask KLM about the JH project models |
| Surface downlights | KLM-4001K, 20W, 20°, 4000K, CRI 90 | Ask about KLM-4001K |
| Outdoor fixtures | KLM-3B076 and KLM-1R150, 3000K | Ask about the outdoor selections |
The configurations describe the supplied package. Confirm the current specification and availability for the model you wish to order.

Products supplied: recessed LED spotlights
The project schedule includes the 12W KLM-DHF-075A-01 recessed spotlight in 15°, 36° and 55° beam versions, with a white trim and white reflector. Keeping the fixture family consistent while selecting different beams gives the project team options for the required light coverage.
For a comparable specification, start with the DHF series below. The published 12W DHF-075A-01 version lists a 75mm ceiling cut-out and an 89mm fitting height. Allow for the driver, connections and installation clearances using the approved drawing. Ask KLM to confirm the beam and driver configuration against your fixture schedule. Beam selection and spacing should follow the project’s lighting calculation.

Products supplied: track and surface-mounted spotlights
This library order combines 15W JH062 surface-mounted spotlights in 24°, 36° and 60° versions with 15W track-mounted versions in 24° and 60°. It also includes 10W JH050 surface-mounted and track-mounted variants. These are separate mounting configurations that need to be identified clearly when requesting a quotation.
If your library schedule mixes track and surface mounting, send KLM the mounting reference, finish and required beam for each item. For track-mounted fittings, include the rail specification so the adapter can be checked before ordering.
Contact KLM to check the JH models supplied for this project.

Products supplied: surface downlights and outdoor fixtures
The supplied indoor range also includes the round KLM-4001K surface-mounted downlight, specified at 20W, 20°, 4000K and CRI 90. The outdoor selection shown in the order includes KLM-3B076 and KLM-1R150 luminaires at 3000K. This extends the supply scope beyond the recessed fittings visible in the interior photographs.
For your project, ask KLM to review the indoor and outdoor fixture lists together. Confirm each outdoor fitting’s protection rating, power supply and installation details using its model-specific documentation.
Ask KLM about KLM-4001K and the outdoor fixtures in this package.
Choosing the beam and colour temperature
What difference do 15°, 36° and 55° beams make?
At a perpendicular distance of 3m from the fitting to a flat target, a simple cone calculation gives approximate beam diameters of 0.79m at 15°, 1.95m at 36° and 3.12m at 55°. The diameter is calculated as 2 × distance × tan(beam angle ÷ 2). This geometric example illustrates coverage only. Actual illumination, overlap and light outside the nominal beam must be assessed using the selected model’s photometric data. The relevant distance is from the fitting to the target surface, such as the reading table.
Is 4000K the right choice for every library?
The indoor fittings in this project’s supply schedule were specified at 4000K. For a new library, compare samples with the actual wall, shelving and furniture finishes and review the reading and storytelling scenes. Agree the colour temperature for each zone with the design team before ordering. Where several fixture types share one space, check their appearance together using the proposed configurations.
Request a library lighting package from KLM
Use this project as a starting point for your own fixture shortlist. KLM can review a package covering recessed spotlights, surface-mounted fittings, track lights and outdoor luminaires. Contact us with your lighting schedule to discuss corresponding models, beam options, finishes and a project quotation.
To start, send KLM three things:
- A floor plan, ceiling plan or existing fixture list.
- The ceiling height, plus shelf height where shelf lighting is needed.
- The main activities in each area, such as reading, browsing, displays or storytelling.
If you already have a specification, include quantities, mounting types, beam angles, finishes and control requirements. You can also contact us while the selection is still being developed, so we can discuss suitable product options and clarify the details needed for a quotation.
Ask for the selected models’ drawings, available photometric files and sample options before final approval.
Send Your Fixture List for a Quote
Questions about a similar project
Can KLM quote several luminaire types for one library?
Yes. This library supply package includes recessed, surface-mounted, track-mounted and outdoor selections. Send your full fixture list so we can check the available matches and identify details that need confirmation.
Can I specify different beams within one product family?
The recessed DHF selection in this order uses 15°, 36° and 55° beams. Ask for the available options for your exact model and use its photometric data to assess the intended layout.
Can I order the same fittings shown in this case?
Reference this library case and the relevant model when contacting KLM. We will check current availability and the required configuration for your quotation.
Planning reference: State Library of New South Wales — Lighting.